Description: Product Attribute
| Attribute Value
|
| Type | Laminated Core |
| Voltage - Primary | 480V |
| Voltage - Secondary (Full Load) | - |
| Current - Output (Max) | - |
| Primary Winding(s) | Dual, Multiple Taps |
| Secondary Winding(s) | Single, Multiple Taps |
| Center Tap | Yes |
| Power - Max | - |
| Mounting Type | Chassis Mount |
| Termination Style | Solder, Quick Connect |
| Product Information | | Resources |
| Manufacturer | SolaHD Emerson | | Product Category | Transformers | | Product Sub Category | Power Transformers | | Series | K-Factor |
| | |
Product Attribute
| Attribute Value
|
| Type | Laminated Core |
| Voltage - Primary | 480V |
| Voltage - Secondary (Full Load) | - |
| Current - Output (Max) | - |
| Primary Winding(s) | Dual, Multiple Taps |
| Secondary Winding(s) | Single, Multiple Taps |
| Center Tap | Yes |
| Power - Max | - |
| Mounting Type | Chassis Mount |
| Termination Style | Solder, Quick Connect |
| K-Factor |
Series Description: SolaHD K-Factor transformers are designed to reduce the heating effects of harmonic currents created by loads like those shown in Chart A. The K-Factor rating is an index of the transformerÂ’s ability to withstand harmonic content while operating within the temperature limits of its insulating system. our K-Factor transformers have UL ratings of K-4, K-13, and K-20.
The SolaHD K-Factor design is a specialized transformer that offers these benefits: Conductors capable of carrying the harmonic currents of non-linear loads without exceeding the temperature rating of the insulation system. A transformer design that takes into account the increase in naturally occurring “stray” losses caused by non-linear loads. These losses cause standard transformers to dramatically overheat and substantially shorten design life. A core and coil design that manages the DC flux caused by triplen harmonics. As these harmonics increase, they cause additional current to circulate in the delta winding. This produces a DC flux in the core which leads to core saturation, voltage instability and overheating. |
- Energy Efficient Compliant to DOE 2016 1
- Conductors to carry harmonics of a K-rated load without exceeding insulation temperature ratings
- UL 1561 Listed up to K-20 rated protection
- Rated temperature rise of 150°C, 220°C insulation
- Shielded for quality power
- Basic design takes “stray losses” into account and functions within safe operating temperatures
- Core and coil design engineered to manage the zero sequence flux caused by triplen harmonics
- Provides 100% rated current without overheating the windings or saturating the core
- Meets transit test requirements for ISTA (International Safe Transit Association) – Test Procedure 1E for packaged-product
- Quiet operation with sound levels 3-6 dB below the NEMA ST-20 requirements
|